Linispeed Jack Major Specifications
Model No. :SJ030H-TUR8
Standard Price
Contact us for details.
Delivery
Contact us for details.
※ | The CAD data contained herein is made available to you via the CAD drawing library; PARTcommunity is provided by CADENAS WEB2CAD Co. |
※ | Please direct your inquiries regarding the CAD data service or PARTcommunity to: CADENAS WEB2CAD Co. TEL: +81 (3) 5961-5031 FAX: +81 (3) 5961-5032 |
Catalogs ・Instruction Manuals
Basic Package
Stroke | Allowable Thrust kN |
Screw OD mm |
Screw Root Dia. mm |
Screw lead mm |
Start-up efficiency % |
Worm Reduction Ratio |
---|---|---|---|---|---|---|
800 | 30 | 36 | 30.7 | 25 | 65 | 6 |
Idling torque without load N・m |
Holding Torque N・m |
Allowable Torque on Input Shaft N・m |
Screw Travel per Turn of Input Shaft mm |
Maximum Input Speed r/min |
Screw shaft rotation torque during allowable thrust N・m |
Moment of Inertia on Input Shaft ×10-4kg・m2 |
---|---|---|---|---|---|---|
6 | 11.5 | 65 | 4.17 | 3000 | 133 | 9.01 |
Table of Dimensions
XA mm | L mm |
Estimated Mass kg |
|
---|---|---|---|
MIN | MAX | ||
202 | 1002 | 878 | 39 |
Transmission Capacity Table
With Linispeed Jacks, efficiency and input capacity/input torque differ from each input rotation speed.
Please confirm the input rotation speed value that you will use.
Input speed r/min |
Speed mm/s |
Total Efficiency % |
Input Capacity Required for Allowable Thrust kW |
Input Torque Required for Allowable Thrust N・m (Note 1 ) |
---|---|---|---|---|
3000 | 208 | 87 | 9.0 | 28.8 |
2500 | 174 | 87 | 7.6 | 29.2 |
2000 | 139 | 87 | 6.1 | 29.0 |
1500 | 104 | 87 | 4.5 | 28.9 |
1000 | 69 | 85 | 3.1 | 29.5 |
500 | 35 | 83 | 1.6 | 30.1 |
100 | 7 | 78 | 0.33 | 31.7 |
Note 1 ) Includes Idling torque without load.
Note 2 ) If the input rotation speed is always 200r / min or less, trouble may occur inside the unit, so please contact us.
Allowable percentage duty cycle
Use Linispeed Jack below the 90 ºC temperature of the reducer surface, including ambient temperatures.
The following table provides guidelines for load rates (% ED) for reducer surface temperatures below 90 ºC *This value is not a guaranteed value. Confirm the temperatures of the reducer surface when actually using Linispeed Jacks.
Ambient Temperature 20゚C | Ambient Temperature 30゚C | Ambient Temperature 40゚C |
---|---|---|
Contact Information