EXTECH logoUser Guide
Heavy Duty CFM Thermo-Anemometer
Model 407113EXTECH 407113 Heavy Duty CFM Thermo Anemometer

Introduction

Congratulations on your purchase of the Extech 407113 CFM meter. This handheld meter can display Air Flow (CFM) with Area or Air Velocity with Temperature on a 10,000-count (0 to 9999) dual display LCD. Other functions include MIN/MAX Record/Recall, RS-232 PC interface, and Data Hold. The metal vane sensor offers rugged durability and higher temperature withstand than comparable devices. Careful use of this meter will provide years of reliable service.

Specifications

General Specifications

Display Dual Display Multi-function 10,000-count (0 to 9999) LCD
Measurements Air Velocity: m/s, km/h, ft/min, knots, mph;
Air Flow: CMM (m³/min) and CFM (ft³/min); Temperature: °C and °F
Data Hold Freezes displayed reading
Sampling rate One (1) reading per second
Sensors Air velocity/flow sensor: Metal angled vane arms with low-friction ball bearing. Temp. Sensor: Precision thermistor
MIN/MAX Records/Recalls lowest and highest readings
Auto Power OFF Automatic shut off after 15 minutes
PC Interface RS-232 Serial Communications (16-bit data stream)
Over range indication 1___ appears on the LCD
Low battery indication LBT appears on the LCD
Power supply 9V Battery (consumption 8.3mA approx.)
Operating conditions Meter: 32 to 122 F (0 to 50º C); 80% RH max.
Sensor: 32 to 175º F (0 to 80º C)
Dimensions / Weight Main instrument: 7.1 x 2.8 x1.3″ (180 x 72 x 32mm)
Sensor head: 2.8” (72mm) diameter
Weight 0.84 lbs. (381g) for meter and sensor

Range Specifications

Air Velocity Measurements Range Resolution Accuracy (%rdg)
m/s (meters per second) 0.50 – 35.00 m/s 0.01 m/s ± (2% + 0.2m/s)
km/h (kilometers per hour) 1.8 — 126.0 km/h 0.1 km/h ± (2% + 0.8km/h)
ft/min (feet per minute) 100 — 6890 ft/min 1 ft/min ± (2% + 40ft/min)
mph (miles per hour) 1.1 — 78.3 mph 0.1 mph ± (2% + 0.4m/h)
knots (nautical miles per hour ) 1.0 to 68 knots 0.1 knots ± (2% + 0.4knots)
Air Flow Measurements Range Resolution Area
CMM (cubic meters per minute) 0-999,900 m³/min 0.001 to 100 0 to 9,999m²
CFM (cubic feet per minute) 0-999,900 ft³/min 0.001 to 100 0 to 9,999ft²
Air Temperature Range Resolution Accuracy
32 to 175°F (0 to 80°C) 0.1° F/C 1.5°F (0.8°C)

Meter Description

EXTECH 407113 Heavy Duty CFM Thermo Anemometer - Meter Description

  1. Sensor Input
  2. RS-232 PC Interface jack
  3. LCD Display
  4. Vane
  5. Rubber Holster
  6. Keypad
  7. Battery compartment (rear)

Note: To access the rear battery compartment, first remove the rubber holster that jackets the meter.

Operation

Air Velocity Measurements

  1. Connect the sensor to the sensor input jack on top of the meter.
  2. Turn on the meter using the Power button.
  3. Select the VELOCITY function using the FLOW / VELOCITY button. The LCD will display VEL when the velocity mode is selected.
  4. Select the desired temperature units using the C/F select button. The LCD will reflect the current unit selection.EXTECH 407113 Heavy Duty CFM Thermo Anemometer - Air Velocity Measurements
  5. Select the desired air velocity units using the UNIT button. The LCD will reflect the current unit selection.
  6. Place the sensor in the air current to be measured with the EXTECH 407113 Heavy Duty CFM Thermo Anemometer - icon symbol on the inlet side of the vane (see diagram).
  7. View the air velocity and temperature readings on the LCD Display. The large main LCD display shows the Air Velocity reading. The lower LCD sub-display shows the temperature reading.

Data Hold

  1. While taking measurements, press the HOLD button to freeze the LCD reading.
  2. The HOLD indicator will appear on the LCD when the display is in Data Hold mode.
  3. Press HOLD again to return to normal operation.

Maximum and Minimum Recording
The 407113 allows the user to record and view the highest (MAX) and lowest (MIN) readings.

  1. Press the RECORD/RECALL button once. The REC indicator will appear on the display and the meter will begin recording the MAX and MIN values.
  2. Press the RECORD/RECALL button to stop the MAX/MIN recording and display the maximum reading. The MAX indicator along with the maximum reading will appear on the LCD display
  3. Press RECORD/RECALL again to view the minimum value. The MIN indicator along with the minimum reading will appear on the LCD display.
  4. To return to normal operation, press and hold the RECORD/RECALL button for approx. 3 seconds. The display indicators REC, MAX, and MIN will disappear.

NOTE: Placing the meter in the RECORD/RECALL mode by pressing the RECORD/RECALL button disables the AUTO POWER OFF feature.
NOTE: Handle the vane carefully. If the metal vane blades are inadvertently bent or damaged erroneous readings may result.

Air Flow (Volume) Measurements (CMM / CFM)

  1. Connect the sensor to the sensor input jack on top of the meter.
  2. Turn on the meter using the POWER button.
  3. Select the FLOW mode using the FLOW/VELOCITY button. The LCD will display FLOW CFM or FLOW CMM when the flow function has been selected.
  4. Select the desired air flow units: CMM (cubic meters per minute) or CFM (cubic feet per minute) using the UNIT button. The LCD will reflect the selection.
  5. Measure the dimensions of the duct or vent and calculate the area in square feet or square meters
    Note: If the dimensional measurements are made in inches (or cm), convert them feet (or meters) before calculating the square area.
  6. Press the AREA button to begin entering the area in m² or ft². Use the Up button to increment the flashing digit, use the Down Buttons button to decrement, use the  button to select the next digit, and use the • button to set the decimal point.
  7. Press the ENTER/RESET button after the area value has been entered. The bottom display will indicate the area entered in ft² or m². The main LCD displays the Air Flow in CFM (cubic feet per minute) or CMM (cubic meters per minute). If the CFM or CMM reading exceeds 9999, use the displayed X10 or X100 multiplier to calculate the reading.
  8. Note that for FLOW measurements, three modes apply: The normal, default mode, where the actual flow is indicated and the two modes described below under 2/3 MAX Flow and AVG Flow.
    Note: The temperature function is not active in the FLOW mode.

2/3V MAX Flow Mode
In this mode the meter will display two-thirds the measured Flow (Volume). To access this mode, ensure that the meter is in the FLOW mode (via the FLOW/VELOCITY button) and then press the FLOW MODE button until the 2/3V MAX display icon appears. Now the Flow display will be 2/3 the actual measurement. To return to the normal display mode, press the FLOW MODE button until the 2/3VMAX and the AVG icons switch off.

AVG (Average) Flow Mode
In this mode the meter will display the AVERAGE Flow for up to 20 readings. To access this mode, ensure that the meter is in the FLOW mode (via the FLOW/VELOCITY button) and press the FLOW MODE button until the AVG display icon appears. Now each time the AVG/START button is pressed a reading will be taken and averaged. The lower LCD display becomes a 20-reading counter and with each reading taken the counter is incremented. Allow 3 or 4 seconds between AVG/START button presses for the display counter to update. The main LCD displays the averaged Air Flow value. To return to the normal display mode, press the FLOW MODE button until the AVG icon switches off.

RS-232 PC Interface
The 407113 is equipped with a 3.5mm phone jack (meter top) for connection to a PC for data acquisition purposes. For streaming of data to a PC via the RS232 Output jack, the optional 407001-USB kit (RS232 to USB cable and driver CD) along with the 407001 software (available free at www.extech.com) are required. Instructions for use are provided with the data acquisition software/hardware kits.

Battery Replacement
When the LBT icon appears on the LCD, the 9V battery must be replaced.

  1. Remove the rubber holster that surrounds the entire meter
  2. Slide off the rear battery compartment
  3. Replace the 9V battery
  4. Affix the battery compartment cover and the meter holster

Useful Equations and Conversions

Area equation for rectangular or square ductsEXTECH 407113 Heavy Duty CFM Thermo Anemometer - rectangular or square ductsArea equation for circular ductsEXTECH 407113 Heavy Duty CFM Thermo Anemometer - circular ductsCubic equations
CFM (ft³/min) = Air Velocity (ft/min) x Area (ft²)
CMM (m³/min) = Air Velocity (m/sec) x Area (m²) x 60
NOTE: Measurements made in inches must be converted to feet or meters before using the above formulae.

Unit of Measure Conversion Table

m/s ft/min knots km/h MPH
1 m/s 1 196.87 1.944 3.6 2.24
1 ft/min 0.00508 1 0.00987 0.01829 0.01138
1 knot 0.5144 101.27 1 1.8519 1.1523
1 km/h 0.2778 54.69 0.54 1 0.6222
1 MPH 0.4464 87.89 0.8679 1.6071 1

Warranty 
FLIR Systems, Inc. warrants this Extech Instruments brand device to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department for authorization. Visit the website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. FLIR Systems, Inc. specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. FLIR’s total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied.

Calibration, Repair, and Customer Care Services

FLIR Systems, Inc. offers repair and calibration services for the Extech Instruments products we sell. NIST certification for most products is also provided. Call the Customer Service Department for information on calibration services available for this product. Annual calibrations should be performed to verify meter performance and accuracy. Technical support and general customer service is also provided, refer to the contact information provided below.

Support Lines: U.S. (877) 439‐8324; International: +1 (603) 324‐7800 
Technical Support: Option 3; E‐mail: support@extech.com
Repair & Returns: Option 4; E‐mail: repair@extech.com
Product specifications are subject to change without notice
Please visit our website for the most up‐to‐date information www.extech.com
FLIR Commercial Systems, Inc., 9 Townsend West, Nashua, NH 03063 USA

Copyright © 2014 FLIR Systems, Inc.
All rights reserved including the right of reproduction in whole or in part in any form
www.extech.com

Documents / Resources

EXTECH 407113 Heavy Duty CFM Thermo Anemometer [pdf] User Guide
407113 Heavy Duty CFM Thermo Anemometer, 407113, Heavy Duty CFM Thermo Anemometer, Duty CFM Thermo Anemometer, CFM Thermo Anemometer, Thermo Anemometer, Anemometer

References

Leave a comment

Your email address will not be published. Required fields are marked *